Floodline Leak Detection
Early warning of leaking liquids:- WATER - OIL - CHEMICALS

Often unnoticed until too late, leaks and floods are amongst the most common causes of damage, disruption and loss in any building with important assets. A single drip can corrupt a computer network, a steady trickle could ruin priceless works of art and a serious flood will probably result in chaos for any organisation.

With the modern architectural trend towards services hidden in raised floors, ceiling voids and ducts the need for leak monitoring and alarm systems becomes more crucial. All sites which have water services, drains, air conditioning and sprinkler systems are at risk.

FLOODLINE offers the most comprehensive and sophisticated range of liquid leak detection products and early warning systems. Many hundreds of FLOODLINE installations are in current use in areas ranging from the computer rooms of international banks, dealing rooms of major financial institutions, Royal palaces, important Government sites and telephone exchanges to name but a few.

The system employs specially designed water sensing devices strategically placed at various danger points within the area being monitored. These are connected in zones to a centrally located control panel. An audible alarm combined with clear visual indicators show the location and type of any alarm and the status of the rest of the system which continues to monitor normally.

The system incorporates:

FLOODLINE products are designed and manufactured in the UK. Protech Systems offers a full installation and maintenance service in the UK and is pleased to offer expert assistance with the design and application of these systems for projects anywhere in the world.

Protech Systems offer the following assistance:

  •  Budget Advice
  •  System Design
  •  Installation, Commissioning and Maintenance (UK only)
  •  Full Installer Support and Engineer Training
  •  After Sales Service and Back-up
  •  Full Spares and Upgrade Exchange Service

FLOODLINE Control Panel - 4, 8, 16, 32, 64 and 96 Zone
Fully featured, mains operated stand-alone control system complete with comprehensive range of visual and audible alarm and status indicators, operator controls, integral back-up battery and outputs for connection to remote monitoring stations, BMS etc.

  "Strings" of multi-zone detection cables/tapes, and/or any number of point, pad, pipe-in-pipe or oil sensors can be connected singly, in groups or in differing combinations to the same control panel giving versatility and true "mix and match" flexibility.

A leak in any zone causes the zone LED to flash in unison with the LEAK warning LED. Likewise a system fault caused by accidental damage or disconnection of the detection sensor network and leader cables will cause the LED of the affected zone to flash in unison with the SYSTEM FAULT warning LED. In any event the buzzer sounds and the appropriate output relays operate. A MUTE button silences the buzzer and "accepts" the alarm. The KEY-SWITCH cancels the outputs while the problem is sorted out.

 

Control Panel Basic Specifications
Sizes 4, 8, 16, 32*, 64* and 96* Zones (*special order)
Function Water/Liquid detection (other types sensing devices can be incorporated - must be 12VDC and give a held, changeover output.)
Power 110/240 VAC, 50Mhz mains operated, 12VDC internal. Battery back-up.
Construction Powder coated steel. Special materials and finishes to order.
Dimensions 4, 8 & 16 Zone Units -280 mm x 206 mm x 118 mm (details of larger capacity units available on request.)
Fixing Surface mounted. (Other variations to special order)
Output 1/ Detection: volt free double pole changeover relay - leak in any zone
2/ System fault: volt free single pole changeover relay - system fault in any zone
3/ Power failure: volt free single pole changeover relay - internal DC supply failure
Output Options Detection - individual volt free single pole changeover relay per zone. Options: 4-20mA, serial connection etc.


Back to Top

 

Multi-Zone Water Detection Cable/Tape Sensor
The unique "Multi-Zone" construction of this water sensitive cable, or tape, allows it to be sub-divided into many separately reporting detection zones, of any length, along ONE continuous length of cable.

Applications:

  •  Below raised floors or in ceiling void following runs of mains, heating or chilled water pipes, condensate drains, etc.
  •  Laid in loops or wave pattern for general monitoring of larger areas
  •  Tie-wrapped to individual pipes
  •  Laid around the base of an item of plant, apparatus or tank
  The detection cable will dry out once the problem has be sorted out and it can be wetted and dried any number of times. In the event of accidental damage or bad contamination then only the affected part need be cut out and a new section easily spliced in.

The detection cable can be connected direct into the Control Panel or via multi-core leader cable . Special FLOODLINE Junction Boxes are supplied for leader/detection cable connection and these are also used for zone-changes and at end of line.

 

Multi-Zone Water Detection Cable/Tape Sensor Specifications
Length Up to 1000m per single zone or group of zones. Supplied in 100m rolls for cutting / connection on site or can be pre-connected in the factory.
Fixing Commonly available "P" clips, self-adhesive clips etc. Plastic cable ties to attach to pipes.
Labels Warning and identification labels available
Leader - Commonly available multi-core double insulated 7/0.2 alarm or comm’s cable or similar.
- LSF Zero Halogen leader cables can be supplied


Back to Top


Sensors

 

Point Sensors
A compact device for vertical or horizontal mounting. Water touching its stainless steel probes causes the alarm to be activated. Nearly always used with the coated metal Floodline Guard Plate for heavy duty physical protection, fixing assistance and level adjustment.

The Point Sensor is used in areas where Detection Cable could be easily damaged or where some wetting or spillage is expected or of little concern. For example a plant room or basement.

 


 

Pad Sensors
A lightweight pliable plastic detection pad used for sensitive detection under specific danger points such as valves or pipe joints or wrapped around them. Also useful in confined spaces.

A removable fabric cover assists absorbency and protects the sensing surfaces. After wetting, the cover can be removed for drying or replaced with a spare

 


 

Pipe Sensors
Monitors the space between the inner and outer pipes in double containment pipe systems used in critical areas or where the pipe contents may be particularly damaging or harmful. The device can also be used in overflow pipes to incorporate a "tell-tale" alarm into the system.

The Floodline Pipe-in-pipe sensor is offered in two versions: for water based liquids and for oils.

A variety of housings are available the most usual being sealed in a ½" BSP male fitting to screw into an equivalent female threaded socket provided at strategic points in the outer pipe.

Alternatively the device can be inserted directly into the cavity, or annulus, created between the inner and outer pipes

 

 

Sensor Specifications
Type Point Sensors Pad Sensors Pipe Sensors
Detection Water contacts across stainless steel probes. Multiple re-use. Instant return to use. Double or Single sided. Multiple re-use. Dry and return to use. Liquid touches the tip of the unit. Multiple re-use. Instant return to use.
Construction High density plastic body, stainless steel probes. Tough, flexible, plastic sheet. Bonded "carbon loaded"
detection tracks. Absorbent fabric envelope.
High density plastic body, stainless steel probes or
plastic tip. Sealed unit.
Dimensions 71 mm x 44mm x 25mm 400 mm x 300 mm x ca 1mm Length of body approx. 70mm, diameter 30mm (1/2" BSP unit). 20mm dia x 100mm long (insertion unit)
Mounting Options - Base of wall or apparatus (Guard Plate optional).
- Floor, free standing or fixed (Guard Plate Tank/Sump etc. requires special bracket plus
immersion proofing kit.)

Connected in any number and/or in any combination with other Floodline sensors.

Fixing: Lay loose, pin/glue at corners or tie-wrap/tape.

Connected in any number and/or combination with other
Floodline sensors to any FLOODLINE system.
Leader Cables Commonly available Multi-core alarm or comms type cable as before. LSF 0H. Commonly available Multi-core alarm or comms type cable as before. LSF 0H. 5m pre-fitted LSF 0H Multi-core alarm or comms type
cable.