AT-SZA Single Zone Alarm
|

AT-SZA Single Zone Alarm
|
|
Description
The AquiTron™ AT-SZA Single Zone Alarm is designed for use with all TraceTek® sensing cables,
AquiTron™ probes and other sensing devices to detect leaks. The AT-SZA provides both visual and
audible indication when a leak or cable fault has occurred and has relay contacts to connect to other
external alarm equipment, BMS and PLC’s.
Simple operation
The operator silences the SZA alarm by pressing the mute button on the front face plate.
The LED’s located on the front face plate indicate Power, (mains or battery back-up),
Alarm, Leak alarm and Cable break. Once the alarm has been silenced, the red Alarm LED will stop
flashing to indicate the system has been acknowledged and the appropriate Leak or Cable break LED
will be illuminated. Once the cause has been located and corrected the corresponding LED will automatically
be extinguished, and the panel can be Reset. Pressing the Reset
button also resets the volt free alarm relay contacts.
Versatile design
The SZA metal enclosure can be easily mounted to a wall or other flat surface.
A semi-flush mounting flange is also available. The enclosure is lockable, has an IP54 rating
and a 90 decibel audible alarm. An auxiliary remote alarm (AT-RAP) can be added to the system
and located in remote positions such as reception areas and security rooms. The AT-SZA unit
operates on 230/120Vac (50/60HZ) and 12Vdc. A battery enclosure unit (AT-BU) for 72-hour operation
is also available.
Applications
The AT-SZA is ideally suited for simple integration into centralised
monitoring systems for computer rooms or large facilities, as well as
interfacing into control systems for air conditioning and fan coil units,
pump, booster and generator sets. Typical applications include monitoring leaks that could
occur around individual air-handling units, water-cooled machinery, tanks, pumps, sumps,
lift pits or other locations.
|
Back to Top
MZA Multiple Zone Alarm Panel
|

MZA Multiple Zone Alarm Panel
|
|
Description
The AquiTron™ MZA multiple zone alarm panel is designed for use with all
TraceTek® sensing cables and AquiTron™ (sensors) to detect liquid and refrigerant - gas leaks.
The MZA is capable of monitoring individual sensing zones in any of the following configurations 2, 4, 6 and 8 zones.
Making it a truly versatile panel. The AT-MZA provides both visual and audible indication when a leak or
cable fault has occurred. There are relay contacts to connect each zone to other equipment such as BMS, PLC’s,
other alarm and monitoring systems.
Versatile design
The MZA metal enclosure can be easily mounted to a wall or other flat surface.
A semi-flush mounting flange is also available. The enclosure is lockable, has an IP54
rating and a 90 decibel audible alarm. An auxiliary remote alarm (AT-RAP) can be added to the system for
remote locations such as reception areas and security rooms. The AT-SZA unit operates on 230/120Vac (50/60HZ) and
12Vdc. A battery enclosure unit (AT-BU) for 24-hour operation is also available.
Simple operation
The panel display includes LEDs for each zone. In the event of a leak, the
alarm sounds and the LED indicates the zone here the leak has occurred. The
operator silences the alarm by pressing the external MUTE button.
The LED’s located on the front faceplate indicate Power, (mains or battery back-up),
Alarm, Leak alarm and Cable break. Once the alarm has been silenced, the red Alarm LED will stop
flashing to indicate the system has been acknowledged and the appropriate zone Leak or Cable break
LED will be illuminated. Once the cause has been located and corrected the corresponding LED will
automatically be extinguished, and the panel can be Reset. Pressing the Reset button also resets the
volt free alarm relay contacts. Any loss of system integrity, whether caused by an interruption of power or a
break in a sensing circuit, will be indicated by the panel’s display and the Fault relay contacts.
Applications
The AT-MZA is ideally suited for multiple integration into centralised monitoring systems
for computer rooms or large facilities, as well as interfacing into control systems for air
conditioning and fan coil units, pump, booster and generator sets. There are individual volt free alarm
relays for each of the 8 zones, additional summary relays are included for leak and cable break/power failure.
Remote external connection can also be provided to Speech auto diallers. Typical applications include monitoring
leaks that would occur around individual air-handling units, water-cooled machinery, tanks, pumps, sumps, lift pits
or other locations.
|
Back to Top
AT-DIM
|

AT-DIM
|
|
Description
The AquiTron™ AT-DIM offers a low cost option for liquid leak detection. It is designed for use with all
TraceTek® sensing cables, AquiTron™ probes and other sensing devices to detect leaks. The AT-DIM provides visual
indication when a leak or cable fault has occurred and has relay contacts to connect to
other external alarm equipment.
Simple Operation
Three LED’s to indicate the operating status of the unit:
- POWER - alarm unit power
- FAULT - sensor integrity
- LEAK - liquid detected
In addition, when either a leak or fault is detected, the AT-DIM activates the relay.
Versatile design
The compact plastic enclosure of the AT-DIM alarm module can be easily mounted
to a wall or other flat surface. Its small size makes it ideal for installation where space
is at a premium, or where an unobtrusive appearance is desired.
Applications
The AT-DIM is ideally suited for simple integration into centralised monitoring systems (BMS, PLC’s) for
computer rooms, comms rooms and patch rooms, as well as interfacing into control systems for air
conditioning and fan coil units, pump, booster and generator sets.
Typical applications include monitoring leaks that would occur around individual air-handling units,
water-cooled machinery, single tanks, pumps, sumps or other locations.
|
Back to Top
AT-RAP Remote Alarm Panel
|

AT-RAP Remote Alarm Panel
|
|
Description
The AT-RAP remote alarm panel interfaces to all the TraceTek® and AquiTron™ leak detection panels.
The AT-RAP incorporates an audible and visual (LED) indication when an alarm is present with a
push button to mute the audible alarm.
Available for 230Vac supply inputs with options by special order for 110Vac and 12/24Vac.
Simple Operation
The AT-RAP operates on a closed signal from the volt free contact within the master control panel.
Two LED’s to indicate the operating status of the unit:
Versatile design
The compact plastic enclosure of the AT-RAP can be easily mounted to a wall or other flat surfaces.
Its small size makes it ideal for installation where space is at a premium, or where an unobtrusive appearance
is desired.
Applications
Suitable for installation within reception areas, security rooms, porter lodges and locations were a remote signal is required
POWER - (green LED) alarm unit power
ALARM - (red LEDLeak, cable break or fault
|
Back to Top
AT-OPSEN
|

AT-OPSEN
|
|
The AT-OPSEN Optical liquid detection sensor has been designed for instant detection of fuel oils and any other non aggressive liquids.
The optical sensor can be used with any of the TraceTek® and AquiTron™ leak detection panels and is fully compatible with all TT1000, TT3000, TT5000 and TT7000 system components.
The use of the optical sensor allows the monitoring for leaks in areas where sensing cables would be difficult to install, either because of the harsh operating environment in which detection is required, or the practicality of installing lengths of sensor cable in vulnerable areas. The unit operates on an optical prism which is resistant to all fuel oils and many other liquids. It’s IP67 enclosure makes the unit liquid tight, easily cleaned and reusable.
The probe has been designed for seamless integration into TraceTek detection systems, either with or without sensor cable, to provide a truly versatile sensor system.
For distributed applications, up to 100 probes may be interconnected by a single jumper cable (daisy chain) and monitored for leak location utilising either TTDM-PLUS or TTSIM-1/1A alarm and locating modules, providing leak location in either metres, feet or zones.(see panel data sheets for maximum probe quantities).
Red and green LED’s are provided to indicate power healthy (green) or leak detected (red).
|
Back to Top
®®
AT600A
|

AT600A
|
|
The immersion sensor has been designed for use with the TraceTek® and AquiTron™ leak detection systems and is fully compatible with all TT1000 system components.
The probe has been designed for seamless integration into TraceTek® and AquiTron™ water detection
systems, either with or without sensor cable, to provide a truly versatile sensor system. For distributed
applications, up to 100 probes may be interconnected by a single jumper cable (daisy chain) and monitored for
leak location utilising either a TTDM-PLUS or TTSIM-1/1A alarm and locating modules providing leak location in
either metres, feet or zones.
Application
Applications for the immersion sensor include: overflow pipes for boilers, heating systems, unvented hot
water cylinders, blow down pipes, drainage, tank level control and applications using double containment pipe systems.
|
Back to Top
|
|